<?xml version="1.0">
<nidocument>
<nicomment>
<nifamily displayname="USRP RIO" familyname="USRP RIO">
</nifamily>
</nicomment>
<nierror code="-1074100545">
Invalid parameter. The offset to start reading from or writing to is out-of-range or too high for the subsystem.
</nierror>
<nierror code="-1074100546">
Invalid parameter. The amount of data to read or write is out-of-range or too large for this subsystem.
</nierror>
<nierror code="-1074100547">
The offset plus the amount of data to read or write is out-of-range or too large for this subsystem.
</nierror>
<nierror code="-1074100548">
Invalid parameter. The handle parameter was NULL.
</nierror>
<nierror code="-1074100549">
Invalid parameter. The deviceIdentifiers parameter was NULL.
</nierror>
<nierror code="-1074100550">
Invalid parameter. The serialNumbers parameter was NULL.
</nierror>
<nierror code="-1074100551">
Invalid parameter. The data parameter was NULL.
</nierror>
<nierror code="-1074100552">
The size of the supplied bitstream is too large.
</nierror>
<nierror code="-1074100553">
Invalid parameter. The buffer parameter was NULL.
</nierror>
<nierror code="-1074100554">
The size of the supplied buffer is too small.
</nierror>
<nierror code="-1074100555">
The FPGA device support object is NULL and likely has not yet been created. There is likely an error between the FPGA driver and the board driver.
</nierror>
<nierror code="-1074100556">
Invalid parameter. The value of the subsystem parameter did not correspond to a valid subsystem.
</nierror>
<nierror code="-1074100557">
Configuring the FPGA auto load mode is not supported. The FPGA will always automatically load on a reset or a power event.
</nierror>
<nierror code="-1074100575">
The Synchronization library signature on the host does not match the FPGA. Recompile the FPGA.
</nierror>
<nierror code="-1074100576">
The Synchronization library on the host is not compatible with the FPGA. The FPGA is too new for the host. Upgrade the software.
</nierror>
<nierror code="-1074100577">
The Synchronization library on the host is not compatible with the FPGA. The host is too new for the FPGA. Recompile the FPGA.
</nierror>
<nierror code="-1074100578">
Synchronization failed due to lack of confidence.

The devices may be synchronized even if the required confidence was not met. Synchronization may have failed due to improper system configuration. Refer to the NI-USRP Help for information about how to configure the system for synchronization. For example, if the confidence level reported is approximately 1/CPTR Period percent, the device clocks likely do not have a fixed phase relationship or are not locked to a common reference clock.
</nierror>
<nierror code="-1074100579">
An invalid CPTR adjust value was produced.
</nierror>
<nierror code="-1074100580">
Synchronization failed. The measurement circuit failed to become ready.
</nierror>
<nierror code="-1074100581">
Synchronization failed because the devices did not align with their CPTRs.

Synchronization may have failed due to improper system configuration. Refer to the NI-USRP Help for information about to configure the system for synchronization.

To continue, confirm proper system configuration. Then perform one of the following:
- Retry.
- Change the phase relationship of the device clocks.

Cabling and system configuration affects the phase relationship of the device clocks. Use length-matched cables to reduce static clock phase skew.
</nierror>
<nierror code="-1074100582">
A CPTR Period must be provided for every device participating in synchronization.
</nierror>
<nierror code="-1074100583">
Synchronization failed. The measurement circuit has exceeded the maximum number of attempts to perform a measurement. This can occur only if the measurement circuit is not properly wired or connected on the FPGA block diagram or if the measurement circuit is malfunctioning.
</nierror>
<nierror code="-1074100584">
The device does not contain valid characterization data, which is required to configure reference level, output power, or correct I/Q impairments.
</nierror>
<nierror code="-1074100585">
Specified reference level or output power exceeds the characterized capabilities of the device.
</nierror>
<nierror code="-1074100586">
Specified values exceed the characterized capabilities.
</nierror>
<nierror code="-1074100587">
Invalid reference frequency source. Valid sources are REF IN, Internal, and GPS.
</nierror>
<nierror code="-1074100588">
Timeout waiting for operation to complete.
</nierror>
<nierror code="-1074100589">
Hardware is too old for this version of the Configuration Instrument Design Library.
</nierror>
<nierror code="-1074100590">
Hardware is too new for this version of the Configuration Instrument Design Library.
</nierror>
<nierror code="-1074100591">
Hardware EEPROM Map and/or calibration data is too old for this version of the Configuration Instrument Design Library.
</nierror>
<nierror code="-1074100592">
Hardware EEPROM Map and/or calibration data is too new for this version of the Configuration Instrument Design Library.
</nierror>
<nierror code="-1074100593">
Unsupported or unknown daughterboard ID.
</nierror>
<nierror code="-1074100594">
The Configuration library signature on the Host does not match the FPGA. Recompile FPGA.
</nierror>
<nierror code="-1074100595">
The Configuration library on the Host is not compatible with the FPGA. The FPGA is too new for the Host. Upgrade the software.
</nierror>
<nierror code="-1074100596">
The Configuration library on the Host is not compatible with the FPGA. The Host is too new for the FPGA. Recompile the FPGA.
</nierror>
<nierror code="-1074100597">
The fixed logic on the FPGA is not compatible with the host. The FPGA is too new for the Host. Upgrade the software.
</nierror>
<nierror code="-1074100598">
The fixed logic on the FPGA is not compatible with the host. The host is too new for the FPGA. Upgrade the fixed logic and recompile the FPGA.
</nierror>
<nierror code="-1074100599">
Invalid number of bits for SPI command.
</nierror>
<nierror code="-1074100600">
Invalid LMK04816 SPI instruction.
</nierror>
<nierror code="-1074100601">
Invalid scope or channel specifier.
</nierror>
<nierror code="-1074100602">
Unsupported data section.
</nierror>
</nidocument>